Umbilical line

From Wikipedia, the free encyclopedia
(Redirected from Umbilical artery catheter)
Umbilical Line

An umbilical line is a catheter that is inserted into one of the two arteries or the vein of the umbilical cord. Generally the UAC/UVC (Umbilical Artery Catheter/Umbilical Vein Catheter) is used in Neonatal Intensive Care Units (NICU) as it provides quick access to the central circulation of premature infants. UAC/UVC lines can be placed at the time of birth and allow medical staff to quickly infuse fluids, inotropic drugs, and blood if required. It is sometimes used in term or near-term newborns in whom the umbilical cord stump is still connected to the circulatory system. Medications, fluids, and blood can be given through this catheter and it allows monitoring of blood gasses and withdrawing of blood samples. Transumbilical catheter intervention is also a method of gaining access to the heart, for example to surgically correct a patent ductus arteriosus.[1]

Complications[edit]

The complications of umbilical lines are similar to those of Central venous catheter mainly Infections such as Neonatal sepsis and thrombosis. The most common organisms causing these infections are coagulase negative staphylococci such as staphylococcus epidermidis[2] To avoid catheter-related bloodstream infections checklists and care bundles focused on strict hygiene routines are often recommended.[3][4][5]

Umbilical arterial catheter[edit]

The position of an umbilical arterial catheter is confirmed on plain film. From the umbilicus, the umbilical arterial catheter dives inferiorly and joins the right or left internal iliac artery before turning superiorly to the common iliac artery and aorta. Appropriate positioning of the catheter tip can be either 'high' or 'low.' The high range is judged relative to thoracic vertebra, and is between T6 and T10, to avoid major aortic branches. The low range is relative to lumbar vertebra, and is between L3 and L5. The lower position may be associated with a higher rate of vascular complications such as thrombosis or vasospasm.[6]

Umbilical venous catheter[edit]

Anomalous positioning of the umbilical venous catheter occurs frequently because it is usually inserted without imaging guidance, and confirmed after placement on subsequent plain film, occurring in approximately 50% of first attempts. From the umbilical vein at the umbilicus, the catheter curves superiorly and to the right, joining the left portal vein, passing through the patent ductus venosus to the inferior vena cava and right atrium. Appropriate UVC tip position is in the high inferior vena cava to the low right atrium, typically within 1 cm of the diaphragm. If the UVC tip is proximal to ductus venosus it can lead to administration of intravenous fluids into the portal system, with potential portal vein thrombosis, or, in cases of TPN administration, a TPN abscess.[7]

References[edit]

  1. ^ Divekar A, Gutsol A, Dakshinamurti S (2007). "Transumbilical catheter intervention of ductus arteriosus in neonatal swine". Journal of Investigative Surgery. 20 (5): 313–317. doi:10.1080/08941930701598842. PMID 17972220.
  2. ^ Bizzarro MJ, Shabanova V, Baltimore RS, Dembry LM, Ehrenkranz RA, Gallagher PG (May 2015). "Neonatal sepsis 2004-2013: the rise and fall of coagulase-negative staphylococci". The Journal of Pediatrics. 166 (5): 1193–1199. doi:10.1016/j.jpeds.2015.02.009. PMC 4413005. PMID 25919728.
  3. ^ "BSI | Guidelines Library | Infection Control | CDC". www.cdc.gov. 2020-01-03. Retrieved 2022-03-04.
  4. ^ Björkman L, Ohlin A (March 2015). "Scrubbing the hub of intravenous catheters with an alcohol wipe for 15 sec reduced neonatal sepsis". Acta Paediatrica. 104 (3): 232–236. doi:10.1111/apa.12866. PMID 25399485.
  5. ^ Bierlaire S, Danhaive O, Carkeek K, Piersigilli F (February 2021). "How to minimize central line-associated bloodstream infections in a neonatal intensive care unit: a quality improvement intervention based on a retrospective analysis and the adoption of an evidence-based bundle". European Journal of Pediatrics. 180 (2): 449–460. doi:10.1007/s00431-020-03844-9. PMID 33083900.
  6. ^ Oestreich AE (December 2010). "Umbilical vein catheterization--appropriate and inappropriate placement". Pediatric Radiology. 40 (12): 1941–1949. doi:10.1007/s00247-010-1840-2. PMID 20890597.
  7. ^ Coley BD, Seguin J, Cordero L, Hogan MJ, Rosenberg E, Reber K (December 1998). "Neonatal total parenteral nutrition ascites from liver erosion by umbilical vein catheters". Pediatric Radiology. 28 (12): 923–927. doi:10.1007/s002470050500. PMID 9880632.